Page 304 - Water Loss Control
P. 304
Contr olling Real Losses in the Field—Pr oactive Leak Detection 273
4
1
3
When correlating between
• 1&2 leak will show falsely on tee
• 1&3 leak will show out of racket
• 2&3 leak will show out of bracket
• 1&4 leak will locate correctly
• 2&4 leak will locate correctly
• 3&4 leak will locate correctly
Always use multiple points to locate
leakes!
2
FIGURE 16.11 Tee connection rule.
D
4
2 × 1
TD 4
1
5 3 L= 2I + TD × V
I = D/2 where TD = 0
Location 4 becomes fixed sensor, minimum 3
runs required
•A point 4 to 3
•B point 4 to 5
•C point 4 to 1
Always use multiple points to locate leaks!
FIGURE 16.12 Linear regression of results.