Page 84 - Water Loss Control
P. 84
66 Cha pte r S i x
Water from Own Sources Water Imported
Source 1 Source 2 Source 3
Characteristics Aqueduct Turnout 41 Well Field City Intertie
Type of measuring device Venturi Propeller Venturi
Identification number (may
be serial number) 0000278-A 8759 OC-16
Frequency of reading Daily Weekly Daily
Type of recording register Dial Dial Builder type M
Units registers indicate 100,000 gal gallons Cubic feet
Multiplier (if any) 1.0 1.0 100.0
Date of installation 1974 1990 1978
Size of conduit 24 in 10 in 11.5 in
Frequency of testing Annual 2 years 4 months
Date of last calibration 4/1/2006 8/21/2006 1/15/2006
TABLE 6.4 Source Water Measuring Devices for County Water Company
Subtotal Source 3 Total for all
Own City Intertie sources 1,
2006 By Source 1 Source 2 Sources (water 2, and 3
Month Turnout 41 Well Field (unadjusted) imported) (unadjusted)
January 0 130.34 130.34 104.27 234.61
February 0 195.51 195.51 65.17 260.68
March 130.83 130.34 261.17 0 261.17
April 160.18 260.68 420.86 0 420.86
97.76 0
May 326.53 424.29 424.29
0 81.46
June 368.62 368.62 450.08
0 84.72
July 372.64 372.64 457.36
0 89.61
August 400.89 400.89 490.50
32.59 32.59
September 360.72 32.59 393.31 97.76 425.90
October 160.18 0 192.77 130.34 290.53
November 160.18 0 160.18 97.76 290.52
December 160.18 160.18 257.94
Annual total 2600.95 879.81 3480.76 783.68 4264.44
Daily average, 11.68
million gal/day
TABLE 6.5 Total Water Supply in Million Gallons for County Water Company (Uncorrected)