2-14   WATER AND WASTEWATER ENGINEERING

                            TABLE 2-8
                            Tabulated computations of annual minima for Troublesome Creek at Nosleep
                                                                                                      3
                                                   3
                            Year     Annual minima, m /s  Rank      Return period, years  5% of Minima, m /s
                            1992           0.67              1           22.00                0.034
                            1997           0.85              2           11.00                0.043
                            1988           1.08              3            7.33                0.054
                            1995           1.13              4            5.50                0.057
                            1990           1.15              5            4.40                0.058
                            1996           1.42              6            3.67                0.071
                            2000           1.42              7            3.14                0.071
                            1991           1.46              8            2.75                0.073
                            2004           1.49              9            2.44                0.075
                            1994           1.56             10            2.20                0.078
                            2001           1.61             11            2.00                0.081
                            2002           1.64             12            1.83                0.082
                            2005           1.69             13            1.69                0.085
                            1989           1.83             14            1.57                0.092
                            2003           1.90             15            1.47                0.099
                            1998           1.98             16            1.38                0.099
                            2007           2.15             17            1.29                0.108
                            2006           2.35             18            1.22                0.118
                            1993           2.38             19            1.16                0.119
                            1999           2.92             20            1.10                0.146
                            2008           3.14             21            1.05                0.157



                            theoretical relationship between an annual series and partial series is shown in  Table 2-9 . The
                            partial series is approximately equal to the annual series for return periods greater than 10 years
                            (Langbein, 1949).
                                    If the time period over which the event occurs is also taken into account, the analysis is
                            termed a  partial-duration series.  While it is fairly easy to define a flood as  any  flow that exceeds
                            the capacity of the drainage system, in order to properly define a drought, one must specify the
                            low flow and its duration. For example, if a roadway is covered with water for 10 minutes, one
                            can say that it is flooded. In contrast, if the flow in a river is below our demand for 10 minutes,
                            one certainly would not declare it a drought! Thus, a partial-duration series is particularly rel-
                            evant for low-flow conditions.


                              Low-Flow Duration.  From an environmental engineering point of view, three low-flow
                            durations are of particular interest. The 10-year return period of seven days of low flow has
                            been selected by many states as the critical flow for water pollution control. Wastewater treat-
                            ment plants must be designed to provide sufficient treatment to allow effluent discharge without
                            driving the quality of the receiving stream below the standard when the dilution capacity of the
                            stream is at a 10-year low.
                                 A longer duration low flow and longer return period are selected for water supply. In the
                            Midwest, drought durations of 1 to 5 years and return periods of 25 to 50 years are used in the