Page 109 - Water and wastewater engineering
P. 109
3-6 WATER AND WASTEWATER ENGINEERING
Overhead crane
Traveling Pump motor
screen
Bridge
Bar screen
winch Winch
Discharge via
bridge to water
treatment plant
Railing
Low water
surface
elevation Bar screen
Pump
Sluice gate column
Intake ports
at three Bar screens
elevations
Exterior view: outside Section
of intake port
FIGURE 3-3
Classic tower design with multiple ports.
15.2 m to lake surface
Horizontal baffle Intake screens
Intake crib
Protective blocks
3.3 m
2.74 m Intake conduit
2.3 km to low-lift pump station
Granular fill
FIGURE 3-4
Lake intake crib. Crib is steel octagonal.