Page 280 - Well Control for Completions and Interventions
P. 280

Well Kill, Kick Detection, and Well Shut-In                  273


                Tubing pressure:
                •  Volume pumped 234.5 bbls (10 3/4" x 5 1/2" 1 9 5/8" x 5 1/2"
                   annulus volume).
                    1
                •  4/2 in. tubing capacity 5 125.55 bbls.
                                                           1
                •  234.5 2 125.55 bbls 5 108.95 bbls filling the 5/2 in. tubing.
                •  108.95 bbls/0.0232 bbls/ft. (5/2 in. tubing capacity) 5 4696 ft. of
                                              1
                   fluid above the cross-over.
                •  Oil packer fluid contact in tubing is 4800 2 4696 ft. MD 5
                   104 ft. MD.
                •  104 ft. MD 5 104 ft. TVD.
                •  Oil hydrostatic 104 ft. 3 0.35 psi/ft. 5 36 psi.
                •  Packer fluid hydrostatic (10,925 2 104 ft.) 3 0.433 5 4685 psi.
                •  5790 2 (36 1 4685) 5 1069 psi
                 Step 5: Tubing filled with annulus fluid:
             •  Tubing head pressure:
                •  10,925 ft. 3 0.433 psi/ft. 5 4731 psi.
                •  5790 2 4731 5 1059 psi.
             •  Casing head pressure:
                •  Volume pumped 236.91 bbls (tubing volume).
                                                                  1
                                                          1
                •  Fluid  level  in  casing.  Volume  to  5/2 in. 3 4/2 in.  cross-
                   over 5 234.5 bbls.
                •  236.91 2 234.5 5 2.41 bbl.
                                                  1
                •  2.41 bbls/0.051 bbls/ft. (9/8 in. 3 4/2 in. annulus) 5 47 ft. MD.
                                          5
                •  Kill fluid at 4800 ft. MD 1 47 ft. MD 5 4847 ft. MD.
                •  4847 ft. MD interpolation (using the data supplied in Table 7.1—
                   well deviation survey) gives a TVD of 4835 ft.
                •  Kill fluid hydrostatic 4835 ft. 3 0.53 psi/ft. 5 2563 psi.
                •  Annulus fluid hydrostatic (10,925 2 4835)3 0.433 psi/ft. 5 2638 psi.
                •  5790 2 (2563 1 2638) 5 589 psi (Fig. 7.10).
                 Step 6: Kill fluid reaches SSD:
             •  Volume pumped 5 annulus volume (655.7 bbls).
             •  Annulus pressure:
                •  10,925 3 0.53 psi/ft. 5 5790 psi.
                •  Casing pressure 0 psi.
             •  Tubing head pressure:
                •  10,925 ft. 3 0.433 psi/ft. 5 4731 psi.
                •  5790 2 4731 5 1059 psi.
                                              1
                                      1
                 Step 7, Kill fluid reaches 5/2 in. 3 4/2 in. cross-over in tubing:
                                                                          1
             •  Volume pumped 5 655.7 bbls (annulus volume) 1 125.55 bbls (4/2 in.
                tubing volume) 5 781.25 bbls.
   275   276   277   278   279   280   281   282   283   284   285