Page 281 - Well Control for Completions and Interventions
P. 281
274 Well Control for Completions and Interventions
WHP: 1059 psi.
CHP: 589 psi.
Kill fluid
4847 ft MD
4835 ft TVD
SSD
13,060 MD
10,925 TVD TVD
Figure 7.10 Packer fluid at surface (tubing volume pumped).
• Annulus pressure:
• Kill fluid hydrostatic: 10,925 3 0.53 psi/ft. 5 5790 psi.
• Casing pressure: 0 psi.
• Tubing head pressure:
• Packer fluid hydrostatic: 4790 ft. TVD 3 0.433 psi/ft. 5 2074 psi.
• Kill fluid hydrostatic (10,925 ft. TVD 2 4790 ft. TVD) 3 0.53 5
3156 psi.
• 5790 2 (2074 1 3156) 5 560 psi.