Page 281 - Well Control for Completions and Interventions
P. 281

274                                Well Control for Completions and Interventions


                               WHP: 1059 psi.







                                    CHP: 589 psi.















                                     Kill fluid
                                    4847 ft MD
                                    4835 ft TVD


                                                  SSD
                                                13,060 MD
                                               10,925 TVD TVD









          Figure 7.10 Packer fluid at surface (tubing volume pumped).



          •  Annulus pressure:
             •  Kill fluid hydrostatic: 10,925 3 0.53 psi/ft. 5 5790 psi.
             •  Casing pressure: 0 psi.
          •  Tubing head pressure:
             •  Packer fluid hydrostatic: 4790 ft. TVD 3 0.433 psi/ft. 5 2074 psi.
             •  Kill fluid hydrostatic (10,925 ft. TVD 2 4790 ft. TVD) 3 0.53 5
                3156 psi.
             •  5790 2 (2074 1 3156) 5 560 psi.
   276   277   278   279   280   281   282   283   284   285   286