Page 158 - Materials Chemistry, Second Edition
P. 158

9 Life Cycle Inventory Analysis                                 143

                                            Emission of copper:
                                            0.1mg/L
                                                          Product Y:
                                                          2000kg/year

                                        Process           Wastewater:
                                                          1000m /year
                                                               3




                                                   3
                      Convert the concentration unit to ”kg/m ” and multiply it with
                      the wastewater flow: 0.0001kg/m *1000m /year = 0.1kg/year.
                                              3
                                                    3



                                            Emission of copper:
                                            0.1kg/year

                                                         Product Y:
                                                         2000kg/year
                                        Process






                      Divide all flows by the annual production rate (2000 kg/year)







                                            Emission of copper:
                                               -5
                                            5*10 kg

                                                         Product Y:
                                                         1kg
                                        Process



            Fig. 9.7 Example of the calculation of an emission per reference flow (1 kg of product Y) from a
            wastewater concentration. Dotted arrows indicate input flows not considered in the example