Page 477 - Advanced Design Examples of Seismic Retrofit of Structures
P. 477

420   Advanced Design Examples of Seismic Retrofit of Structures



              TABLE 6.5 Summary of Results for Wall Pairs After GSAP Tests—cont’d

              Model
              No.
              and       Collapse   Principal Retrofit
              Walls     Level      Measures              Comments
              3NE       No         Bond beam, lower internal  Stable behavior in all
                        collapse   horizontal straps, and  tests
                                   vertical center-core rods
              3SW       No         Bond beam, lower internal  Stable behavior in all
                        collapse   horizontal straps, and  tests
                                   vertical center-core rods
              9         VI         None (control model)  Complete collapse of
                                                         gable-end walls
              8NE       No         Partial wood          Stable behavior in all
                        collapse   diaphragms—upper strap  tests
                                   at attic-floor level, lower
                                   straps, and vertical straps
              8SW       No         Partial wood          Stable behavior in all
                        collapse   diaphragms—upper strap  tests
                                   at attic-floor level, lower
                                   straps, and vertical center-
                                   core rods; no lower strap
                                   on west wall
              7NE       No         Partial wood          Stable behavior in all
                        collapse   diaphragms—upper strap  tests
                                   at attic-floor level, lower
                                   straps, and vertical straps
              7 SW      X          Partial wood          Partial collapse of south
                                   diaphragms—upper strap  (in-plane) wall during
                                   at attic-floor level and  test level X
                                   lower straps; no vertical
                                   straps





            6.4.1.5 Comparison of Test Results and Field Observations
            Comparison of laboratory tests and field observations of the Northridge earth-
            quake show good correlation. The important observations can be summarized as
            follows:
            l Below 0.15g, little or no damage was observed in adobe buildings with good
               conditions.
            l Starting around 0.2g, minor and more severe cracks were observed in intact
               buildings and previously damaged structures, respectively.
   472   473   474   475   476   477   478   479   480   481   482