Page 524 - Advanced Design Examples of Seismic Retrofit of Structures
P. 524

Index 467


                material properties, 213         in-plane damage of walls, 24–25
                thickness, 223                   mid-height flexural out-of-plane
                3D model building, 217–220, 220f  cracks, 22
                transverse direction, 217        nonstructural components, 37–38
               shotcreting of infill panels in transverse  out-of-plane failure of URM walls, 20–21
                  direction, 250–253, 254–255t, 256f  partial collapse of jack-arch roofs, 35–36
             Steel strips, 436, 437f             soil and foundation condition, 31–35
             Steel welded mesh, 395, 397f        surrounding walls, 22
             Steel wire mesh, 434–436, 436f      ties in confined masonry buildings, 30
             Steel woven mesh, 395, 397f         walls corners, 27–30
             Straps and reinforcing bars, 396    walls-roof connection, 31
             Strength vs. stability-based design approach,  walls supports, 25–27
                  86–88                        demand-to-capacity parameters
             Strong-motion characteristics, 17   load transfer between the walls, 50–51
             Structural and nonstructural components, 39–40  mortar shear strength, 49–50
             Surrounding walls, 22               seismicity and soil conditions, 50
                                               isolation of the adjacent building, 16, 16f
             T                                 plan, 13, 14f
                                               retrofit measures
             Target building performance level, 6, 7t
                                                 adding tie columns, 92
             Target displacement, 294–296, 295t
                                                 center-core rods, 94
             Through-wall connections, 434, 435f
                                                 external reinforcement, 93–94
             Ties
                                                 ferrocement covering of the walls, 91–92
               columns, 16, 92
                                                 grout and epoxy injection, 92–93
               in confined masonry buildings, 30
                                                 incremental seismic rehabilitation, 89–90
             Torsion, steel frame building, 291
                                                 placement of steel, polymer, or plastic
                                                  grids, 96–97
             U                                   posttensioning, 95
             Unreinforced masonry (URM)          repointing, 92
               analysis procedure                safe room, 95–96
                acceptance criteria, 79–81       shotcrete, 90–91, 97–115
                capacity forces calculations, 75–79  strength vs. stability-based design
                deformation-controlled actions, 73–74  approach, 86–88
                demand forces calculations, 52–55  tying paralleled walls, 92
                force-controlled actions, 74   risks, 13–14
                horizontal distribution of demand forces,  sections, 13, 15f
                  56–73                        seismic damage
                vertical distribution of demand forces,  condition of building during earthquake,
                  55–56                           18–19
               assumptions, 14–17                construction quality, 19
               building configuration            geometrical characteristics, 17–18
                diaphragms, 40–41                seismic intensity and other strong-motion
                irregularity, 43–49               characteristics, 17
                structural and nonstructural components,  seismic rehabilitation elements, 18
                  39–40                          soil and foundation condition, 19
                walls in longitudinal (X) and transverse  view, 13, 15f
                  (Y) directions, 41–42       Upper-wall horizontal elements, 421
               damage classification          URM. See Unreinforced masonry (URM)
                collapse of parapet walls and facades,  US adobe buildings
                  22–24                        comparison of test results and field
                common types of damage, 39        observations, 420–421
                dome roofs, 36                 experimental studies, 403–419
   519   520   521   522   523   524   525   526