Page 154 - APPLIED PROCESS DESIGN FOR CHEMICAL AND PETROCHEMICAL PLANTS, Volume 1, 3rd Edition
P. 154

140                      Applied Process Design for Chemical and Petrochemical Plants





                                                                  Flash Pressure, 2 psig
                                                                  (Lower than either X or Y)







                             Pressure: X,  psig
                             Pressure: Y, pslg             Vapor


                             Condensate                      Flashing
                             From Various              3

                              Headers
                                                           Liquid

                                                                                       I  IF




                                                                                  ’--
                                                                                       I  I
                                                                                       I



                                                                                       I  I  I
                                                                                       I
                                                                                       1
                                                                                       I
                                                                                       I
                                                                                       I
                                                                                       I




                                            Figure 2-53. Typical steam condensate flashing operation.


              psig.  The  calculated  total  equivalent  length  of  pipe,   ’7.  Refer to Figure 2-54 and note that required receiver
              valves, and fittings is 600 feet.                         pressure is not shown, so calculate “factor scale” by
                Using the Sarco chart, Figure 2-54, determine the rec-   previous formula:
              ommended line size for the return line.
                                                                        Data:  h,  = 441 Btu/lb at 450 psig
                1. Upstream steam pressure  = 450 psig                        h,  = 302 Btu/lb  at 90 psig
                2. Condensate load = 9,425 Ibs/hr                             L,  = 886 Btu/lb  at 90 psig
                                                                              -
                3. Return line pressure  = 90 psig                            V = 4.232 cu ft/lb  at 90 psig
                4. Use the Sarco recommendation of 5,000 ft/min
                5. Load factor
                                                                                          36.2 (4.232) (441 - 302)
                                                                        “factor scale” value  =                = 0.092
                                                                                              886 (441 - 180)


                                                                                          53
                                                                      8. Ft/min/lOO#/hr  = - 576
                                                                                               =
                6. Receiver pressure  = 90 psig                                          0.092