Page 281 - Applied Process Design For Chemical And Petrochemical Plants Volume II
P. 281

270                       Applied Process Design for Chemical and Petrochemical Plants

                                     Metal “Rosette”  Redistributor






























                                                                                      OPTIONAL  INSTALLATION
                                                                WITHIN  150 POUND    INsT~LLED BETWEEN TOWER  FLANGES












             Figure 9-12. Metal rosette style redistributor. Used by permission of Norton Chemical Process Products Corp., Bull. TA-80.



                                                            for plastic packing, the bed should not compress or con-
                                                            solidate to create operational limitations.

                                                                             Packing Installation

                                                            Stacked
                                                              Stacked packing is a hand operation and rather costly. It
                                                            is  avoided where possible except for the initial layers on
                                                            supports. Liquid distributed on a stacked packing usually
                                                            flows straight down through the packing immediately adja-
                                                            cent to the point of contact. There is very little horizontal
                                                            liquid flow. Packing patterns perform differently, and are
                                                            illustrated in Figure 9-16A-C.

                                                            Dumped


      Figure 9-13. Typical metal full cross-section redistributor. Used by   Dumping  is  the  most  common  method  of  Packing
      permission  of Norton Chemical Process Products Corp., Bull. TA-80.   installation.  If  possible,  the  tower  should  be  filled  with
   276   277   278   279   280   281   282   283   284   285   286