Page 333 - Battery Reference Book
P. 333

30/4  Primary batteries

             I 1.7r





                                                            1.1
                                                                                107 PA
                                                            0.9
                                                            0.7
                  0   50  100  150 200 250  300  350  400     0   300   600   900   1200  1500
                           Service time (h)                           Service time (h)
                     (a)  No. 384: 35 mA h to 1.3 V;            (c)  No, 301:  100 mA h to 1.3 V;
                 rated at 15 000 R load, starting drain 104 pA   rated at 15 000 R load, starting drain 107 pA





                                                            1.3
                                                            1.1
                                                            0.9                     246 PA
                                                            0.7
                  0     200    400   600    800               0    200   400   600   800
                           Service time (h)                           Service time Ih)
                      (b)  No. 309: 60 mA h to 1.3 V;              (d)  165 mA h to 1.3 V;
                  rated at 15 000 R load, starting drain 107 PA   rated at 6500 R load, starting drain 246 pA
          Figure 30.3  Union Carbide Eveready silver-zinc  cell voltage-discharge  curves: estimated hours of  service at 35°C against closed-circuit
          voltage at stated starting drains and loads and on a 24 h/day schedule (Courtesy of  Union Carbide)

                1.7 r




                1.3                                       >
                                                            1 .o
              0 1.1
              >                                               0   10  20  30  40   50  60  70  80
                                                                       Service time (h)
                0.9
                                                                    (c)  No. S13E and 513:
                0.71   I    I   I    I    I   1                  75 mA h to 0.9 V;  rated at 1.07 mA
                  0    10   20   30   40   50   60
                            Service time (h)
                         (a)  No. S312 and S312E:
                       38 mA h to 0.9 V;  rated at 1 mA

                 1.8 r
              7;  1.6
                                                          c
               0
               ” 1.4                1000 n                0 1.2
                                                          >
               0 1.2   2.56 mA      1.6 mA
              >  1.0                                        1 .o
                   0   20   40   60   80   100  120           0   20   40   60   80   100  120  140
                            Service time (h)                           Service time (h)
                          (b)  No. S41 and 541 E:                       (d)  No. S76E:
                      120 mA h to 0.9  V; rated at 1.6 rnA       190 mA h to 0.9 V;  rated at 2.56 mA
          Figure 30.4  Union Carbide silver-zinc  cell voltage-discharge curves: estimated hours of service at 21°C against voltage at stated starting
          drains raverage drains) and loads and on a 16 h/day schedule (Courtesy of Union Carbide)