Page 340 - Biodegradable Polyesters
P. 340

318  12  Biodegradable Polyesters Polymer–Polymer Composites

                    as additional drawing to increase the orientation of PGA molecules which may
                    improve creep properties. Since PLLA and PGA are condensation polymers
                    there exists the possibility of transreactions between the fibrils and matrix
                    which could be leveraged to enhance the interfacial adhesion and subsequently
                    improve mechanical performance [40, 46, 50]. Clearly many opportunities for
                    improvement are available to be explored in future work.


                    References
                     1. Oxford English Dictionary (2010),  Verdouw, P.D. (1990) Arterial stenting
                       Stent, Oxford University Press.  with self-expandable and balloon-
                       http://www.oxforddictionaries.com/  expandable endoprostheses. Int. J. Card.
                       definition/english/stent?search  Imaging, 5, 163–171.
                       DictCode=all (accessed 2010)  11. O’Brien, B. and Carroll, W. (2009) The
                     2. Murray, C.J. and Lopez, A.D. (1997)  evolution of cardiovascular stent mate-
                       Mortality by cause for eight regions of  rials and surfaces in response to clinical
                       theworld:GlobalBurdenofDisease  drivers: a review. Acta Biomater., 5,
                       Study. Lancet, 349, 1269–1276.  945–958.
                     3. Cardiovascular Media Library (2010)  12. Kastrati, A., Schomig, A., Dirschinger,
                       http://www.medmovie.com/demo2/.  J.,Mehilli,J., vonWelser, N.,Pache,J.,
                     4. Mani, G., Feldman, M.D., Patel, D., and  Schuhlen, H., Schilling, T., Schmitt, C.,
                       Agrawal, C.M. (2007) Coronary stents: a  and Neumann, F.-J. (2000) Increased
                       materials perspective. Biomaterials, 28,  risk of restenosis after placement of
                       1689–1710.                      gold-coated stents: results of a random-
                     5. Hillen, U., Haude, M., Erbel, R., and  ized trial comparing gold-coated with
                       Goos, M. (2002) Evaluation of metal  uncoated steel stents in patients with
                       allergies in patients with coronary stents.  coronary artery disease. Circulation, 101,
                       Contact Dermatitis, 47, 353–356.  2478–2483.
                     6. Köster,R., Vieluf,D., Kiehn, M.,  13. Webster, M.W. and Ormiston, J.A. (2007)
                       Sommerauer, M., Kahler, J., Baldus,  Drug-eluting stents and late stent throm-
                       S., Meinertz, T., and Hamm, C.W. (2000)  bosis. Lancet, 370, 914–915.
                       Nickel and molybdenum contact aller-  14. Finn, A.V., Joner, M., Nakazawa, G.,
                       gies in patients with coronary in-stent  Kolodgie, F., Newell, J., John, M.C., Gold,
                       restenosis. Lancet, 356, 1895–1897.  H.K., and Virmani, R. (2007) Patholog-
                     7. Kraitzer, A., Kloog, Y., and Zilberman,  ical correlates of late drug-eluting stent
                       M. (2008) Approaches for prevention of  thrombosis: strut coverage as a marker
                       restenosis. J. Biomed. Mater. Res. - Part B  of endothelialization. Circulation, 115,
                       Appl. Biomater., 85, 583–603.   2435–2441.
                     8. Serruys, P.W., Kutryk, M.J.B., and Ong,  15. Ormiston, J. and Webster, M. (2007)
                       A.T.L. (2006) Coronary-artery stents. N.  Absorbable coronary stents. Lancet, 369,
                       Engl. J. Med., 354, 483–495.    1839–1840.
                     9. Lemesle, G., Delhaye, C., Bonello, L., de  16. Ferrari, E., Benhamou, M., Cerboni, P.,
                       Labriolle, A., Waksman, R., and Pichard,  and Marcel, B. (2005) Coronary syn-
                       A. (2008) Stent thrombosis in 2008:  dromes following aspirin withdrawal: a
                       definition, predictors, prognosis and  special risk for late stent thrombosis. J.
                       treatment. Arch. Cardiovasc. Dis., 101,  Am. Coll. Cardiol., 45, 456–459.
                       769–777.                      17. Grabow, N., Bünger, C.M., Schultze,
                    10. Van Der Giessen, W.J., Serruys, P.W.,  C., Schmohl, K., Martin, D.P., Williams,
                       Van Woerkens, L.J., Beatt, K.J., Visser,  S.F., Sternberg, K., and Schmitz, K.P.
                       W.J., Jongkind, J.F., Van Bremen, R.H.,  (2007) A biodegradable slotted tube
                       Ridderhof, E., Van Loon, H., Soei,  stent based on poly(l-lactide) and
                       L.K., Van Beusekom, H.M.M., and  poly(4-hydroxybutyrate) for rapid
   335   336   337   338   339   340   341   342   343   344   345