Plants and Equipment                                                                                349


               used almost exclusively for application as induced draft   is when it’s used to provide air for ash or coal transport
               fans and primary air fans for coal pulverizers. You’ll dis-  systems which require some rather high differential pres-
               cover that most air conditioning and ventilation systems   sures. See the following discussion on rotary compressors
               use forward curved fans because they are more efficient   for more information that would apply to blowers.
               at  delivering  large  volumes  of  air  at  low  differential
               pressures. It’s important to note that forward curved   Fan and Blower Control
               fans have a very stretched curve and it’s not at all un-     Control of the flow of gases in systems with fans
               common for the motors on those fans to be overloaded if   and blowers is typically achieved using devices we call
               nothing restricts the air flow.                      dampers that are a leaky version of valves. Sometimes
                    Blowers will have radial blades or backward     the system uses valves or their equivalent when leakage
               curved blades depending on the application and can   is not acceptable. Dampers are not the best method for
               experience the same problems with surging that was   controlling air flow because they are typically made to
               discussed  with centrifugal  pumps.  That surging will   be inexpensive and there isn’t a linear relationship (see
               also occur for the same reasons. It’s seldom encountered   controls) between the damper position and air flow. Op-
                                                                                                     11
               in fan and blower applications but is frequently encoun-  posed blade dampers (Figure 10-91)  provide a better
               tered when compression is involved.                  relationship than parallel bladed dampers. The different
                    An important thing to remember about these
               fans is that they’re centrifugal devices, the differential
               pressure that’s produced by them is a function of the
               flow through the fan and the density of the gas flowing
               through. When the gas is colder a fan will produce a
               higher differential pressure (in terms of inches of water)
               and, because it’s moving denser air, more pounds of gas.
               When a fan is handling gases at higher temperatures
               they will not produce as high a differential and move
               fewer pounds of gas. In many cases the motor on an
               induced draft fan is not big enough to handle cold air
               because the power requirement is significantly higher
               when pumping cold air. That’s why you have to be care-
               ful when starting a boiler with an induced draft fan to
               ensure you do not overload it. Once it’s pumping hot
               flue gas the load on it drops off.
                    That’s also justification for not getting excited
               when a boiler can’t produce full load in the summer
               time. If an F.D. (Forced Draft) fan is installed to collect
               the heated air in the top of the boiler plant it will not
               pump as much air in the summer, when the tempera-
               tures are about 125°F to 130°F but it will in the winter
               when those temperatures are 50° to 60° lower. It is im-
               portant to realize that the fan is moving less air (pounds
               of it) in the summer to reduce excess air because you
               might be running fuel rich. If the boiler is summer tuned
               then you’ll find that excess air is higher in the winter be-
               cause the air is denser than when the boiler was tuned.

               Rotary Blowers
                    Rotary blowers don’t resemble fans, the same con-
               struction is used for compressors and the main reason
               for rotary blowers is to produce high differentials that
               are necessary for material transport systems. Probably   Figure 10-91. Resistance curves & diagrams of parallel
               the only time you’ll see a rotary blower in a boiler plant   and opposed blade dampers