Page 445 - Cam Design Handbook
P. 445

THB13  9/19/03  7:56 PM  Page 433

                                CAM SYSTEM DYNAMICS—RESPONSE               433































                        FIGURE 13.17. Uniform convolution residual vibration spectrum.





            TABLE 13.4  Fourier Analysis when V 0 * is for Uniform Rise V 0 *(0) = 1. ImV i *(2pm) = 0.
            m     2ReV 0 *(2pm)  2ReV 1 *(2pm)  2ReV 2 *(2pm)  2ReV 3 *(2pm)  2ReV 4 *(2pm)
             1        0        -0.810732    -1.032049    -1.088591    -1.107524
             2        0         0            0            0            0
             3        0        -0.090226     0.038224     0.078330     0.092391
             4        0         0            0            0            0
             5        0        -0.032586    -0.008256     0.010152     0.017306
             6        0         0            0            0            0
             7        0        -0.016706     0.003009    -0.000453    -0.002088
             8        0         0            0            0            0
             9        0        -0.010171    -0.001416    -0.000166     0.000711
            10        0         000                                    0
            11        0        -0.006864     0.001550     0.000434    -0.000596
            12        0         000                                    0
            13        0        -0.004962    -0.000469     0.000222    -0.000182
            14        0         000                                    0
            15        0        -0.003770     0.000306    -0.000022     0.000013