Page 445 - Cam Design Handbook
P. 445
THB13 9/19/03 7:56 PM Page 433
CAM SYSTEM DYNAMICS—RESPONSE 433
FIGURE 13.17. Uniform convolution residual vibration spectrum.
TABLE 13.4 Fourier Analysis when V 0 * is for Uniform Rise V 0 *(0) = 1. ImV i *(2pm) = 0.
m 2ReV 0 *(2pm) 2ReV 1 *(2pm) 2ReV 2 *(2pm) 2ReV 3 *(2pm) 2ReV 4 *(2pm)
1 0 -0.810732 -1.032049 -1.088591 -1.107524
2 0 0 0 0 0
3 0 -0.090226 0.038224 0.078330 0.092391
4 0 0 0 0 0
5 0 -0.032586 -0.008256 0.010152 0.017306
6 0 0 0 0 0
7 0 -0.016706 0.003009 -0.000453 -0.002088
8 0 0 0 0 0
9 0 -0.010171 -0.001416 -0.000166 0.000711
10 0 000 0
11 0 -0.006864 0.001550 0.000434 -0.000596
12 0 000 0
13 0 -0.004962 -0.000469 0.000222 -0.000182
14 0 000 0
15 0 -0.003770 0.000306 -0.000022 0.000013