Page 520 - Construction Waterproofing Handbook
P. 520

15.4   CHAPTER FIFTEEN

                              d.  Flow Direction:  Flow shall be measured on only one side of the core.  Where the
                                  core  geometry differs  in  principal  directions,  flow  shall  be  measured  in  both
                                  directions, simulating water flowing vertically  down a wall and horizontally across
                                  the face of the wall to accurately determine maximum flow rate in critical  principal
                                  direction.
                        2.    Certificates (Qualification Data):  Submit product certificates signed by manufacturer
                              certifying materials  comply with specified performance characteristics and physical
                              requirements,  showing full  time  quality  control,  and  that  prefabricated  drainage
                              composites are being supplied  by a single-source manufacturer.

                  F.    Closeout Submittals:
                        1.    Warranty:  Submit warranty documents specified herein.
                        2.    Project Record Documents:  Submit project record documents for installed materials
                              in accordance with Division 1 Project Closeout (Project Record Documents)  Section.
           1.05  QUALITY ASSURANCE

                  A.    Qualifications:
                        1.    Installer  Qualifications:  Installer  experienced  (as  determined  by  contractor)  to
                              perform work of this section, who  has specialized in the installation  of work similar to
                              that  required  for  this  project,  who  can  comply  with  manufacturer's  warranty
                              requirements,  and  who  is  an  approved  applicator  as  determined  by  drainage
                              manufacturer.
                        2.    Manufacturer  Qualifications:  Manufacturer  capable  of  providing  field  service
                              representation during construction, approving acceptable  installer, application method
                              and conducting final inspection  of the drainage composites assembly.

           Ed Note:  If mock-up is required for special project requirements or Job conditions, add text.  Typically mock-ups may not be required.
                  B.    Pre-lnstallation  Meetings:  Conduct pre-installation meeting to verify project  requirements,
                        substrate  conditions,  manufacturer's  installation  instructions  and  manufacturer's warranty
                        requirements.
                 C.     Pre-lnstallation Testing:  In accordance with manufacturer's recommendations and warranty
                        requirements, conduct pre-installation testing of substrates to receive drainage composites.

          FIGURE 15.1 (Continued)  Guide specification for section 2715, prefabricated drainage system. (Courtesy TC MiraDRI)