Page 529 - Construction Waterproofing Handbook
P. 529

GUIDE SPECIFICATION FOR WATERPROOFING  15.13
                        Attach the Miradrain 9000 panels by either placing temporary ballast  on top of the Miradrain or
                        adhering  the  panels  to  the waterproofing membrane  with  Mirastick  construction adhesive  or
                        Mirabond two sided tape.

                        Connect adjacent panels at the longitudinal edge by pulling the filter fabric back to expose the
                        flange.  Place a small amount of two sided tape or Mirastick on the flange.  The flangeless edge
                        of the panel should be placed on top of the flange of the adjacent panel and butted  dimple to
                        dimple.  All connections should be completed in shingle fashion so that moisture will flow with the
                        overlap and not against it.  Overlap fabric in the direction of water flow.  Cover all terminal edges
                        with the filter fabric flap by tucking it behind the core.
                        Miradrain 9000 should be channeled  into an internal drain or perimeter drain system.

                        Concrete, sand, grout, or pavers may be placed directly on the Miradrain 9000 fabric side.  Caution
                        should be taken not to place point loads on the Miradrain that  might puncture the filter fabric on
                        the  Miradrain.  When concrete is poured against Miradrain,  use proper chuting techniques  and
                        avoid high drop heights.
                     2.  Floor Slabs and Concrete Lined Channels - MD-6000 or MD-9000
                        The subgrade shall be graded to a 2% minimum slope and clear of rubble,  rock, large soil clods,
                        etc.  The  Miradrain  should be placed  fabric  side down,  directly  on the  subgrade.  Installation
                        should proceed from the higher elevation of the slope and work downward.  Connection of panel
                        ends shall be achieved with four row dimple overlapping and taping of terminal edges.

                     3.  Planters - MD-9000
                        Miradrain 9000 should  be placed fabric side to the inside (soil side) of the planter.  The planter
                        walls should be covered with Miradrain 9000.  Allow a 3" (7.5 cm) fabric overlap at the bottom of
                        vertical panels in order to cover the intersection of wall and bottom sections.  Any exposed panel
                        edges must be covered with supplemental pieces of fabric to prevent soil intrusion into the flow
                        channels.

              3.05   DISCHARGE CONNECTIONS
              A.     Drainage - Where drainpipe is indicated,  place the drainpipe next to the core.  Wrap the drainpipe or
                     rock-pipe drain combination with an auxiliary piece of Mirafi filter fabric.
                     At weep holes, cut a hole in the core corresponding to the size and location of the weep hole.  Avoid
                     cutting a hole in the fabric by cutting the backside of the core between the dimples.  A four dimple
                     square area cut between the dimples (2 1/2 square inch) should be sufficient for most  applications.
                     Plaza  Drains - Create openings  in the Miradrain core to correspond with all discharge  holes in the
                     drain at the structural deck level.  Fabric must be placed over these holes to prevent intrusion of soil,
                     grout, sand, or concrete into the drainage core.
             FIGURE 15.1 (Continued)  Guide specification for section 2715, prefabricated drainage system. (Courtesy TC MiraDRI)
   524   525   526   527   528   529   530   531   532   533   534