GUIDE SPECIFICATION FOR WATERPROOFING  15.11
              PART 3 EXECUTION

              3.01  MANUFACTURER'S  INSTRUCTIONS/RECOMMENDATIONS
                     A.    Compliance:  Comply with manufacturer's product data, including  product technical  bulletins,
                           product catalog installation instructions  and product packaging  instructions.
              3.02  EXAMINATION

                     A.    Site  Verification  of  Conditions:  Verify  substrate  conditions  (which  have  been  previously
                           installed  under  other  sections)  are acceptable  for  product  installation  in accordance with
                           manufacturer's  instructions.  Do  not  proceed  with  drainage  installation  until  substrate
                           conditions are acceptable  for compliance with manufacturer's warranty requirements.

              3.03  PREPARATION
                     A.    Adjacent Surfaces Protection:  Protect adjacent work areas and finish surfaces from damage
                           during installation  operations.
                     B.    Concrete Surface Preparation:  Prepare concrete surfaces to receive drainage  composite.
                           Surfaces  shall  be smooth,  free of depressions,  voids, protrusions,  clean and free of other
                           surface contaminants  which  may impair  the performance of drainage  and manufacturer's
                           warranty  requirements.
                           1.    Cast-in-Place Concretes:  Decks shall be monolithic,  smooth, free of voids, spalled
                                 areas, laitenance, honeycombs, and sharp protrusions.  Refer to Division 3 Concrete
                                 Section  for  concrete  strength,  density,  finish,  curing  methods  and other  concrete
                                 requirements.
                           2.    Precast  Concrete  Decks:  Decks  shall  be  mechanically  secured  to  minimize
                                 differential  movement and each joint  between precast  units shall  have an installed
                                 backer rod.  Grout precast units as recommended by manufacturer.
                           3.    Shotcrete:  Surface shall be monolithic  and smooth with no indulations,  irregularities
                                 or exposed wire mesh.

                     D.    Substrate Cleaning:  Clean substrate which  is to receive drainage.  Remove loose debris and
                           other harmful contaminants  which will affect performance of drainage  composite.

              I Ed Note:  Coordinate below article with Part 2 Products article to include each product  requiring installation.

             I DWG Coord Note:  Coordinate below article with Nlcolon/Mirafi recommended  drainage  details number consecutively No. 1 thai No. 11
             FIGURE 15.1 (Continued)  Guide specification for section 2715, prefabricated drainage system. (Courtesy TC MiraDRI)