7.42                      CHAPTER SEVEN

           The seismic response coefficient C  is determined from Eq. (7.50):
                                    s

                                     C =  S  DS                      (7.50)
                                         ⎛  R ⎞
                                      s
                                         ⎝  I ⎠
         where S  = the design spectral response acceleration parameter in the short period range
              DS
               R =  structural response modification factor for the seismic force–resisting system
                  as listed in ASCE 7-05 Table 12.2-1 (discussed in the next section).
               I = importance determined based on the occupancy category of the building
                = 1.0 for buildings in Occupancy Category I and II
                = 1.25 for buildings in Occupancy Category III
                = 1.5 for buildings in Occupancy Category IV.
         The value of the seismic response coefficient C  determined from Eq. (7.50) is subject to
                                           s
         an upper limit and a lower limit. Its value need not exceed the value given by Eqs. (7.51)
         or (7.52) as applicable:

                               C =  S  D1    for T ≤ T               (7.51)
                                s   ⎛  R ⎞        L
                                   T
                                    ⎝  I ⎠
                                    D1
                               C =  ST L    for T > T                (7.52)
                                s    ⎛  R ⎞        L
                                   T  2
                                     ⎝  I ⎠
         The value of C  given by Eq. (7.50) may not be less than the value given by Eq. (7.53)
                    s
         (ASCE 7-05 Suppl. 2):
                                 C  = 0.044S  ≥ 0.01                 (7.53)
                                          DS
                                   s
         In addition to the lower limit for C  given by Eq. (7.53), there is an additional lower limit for
                                 s
         C  for structures located where the spectral parameter S  is equal to or greater than 0.6g:
          s
                                                1
                                         05 .  S 1
                                     C =                             (7.54)
                                         ⎛  R ⎞
                                      s
                                         ⎝  I ⎠
         where S  = the design spectral response acceleration parameter at a period of 1 s

              D1
               T = fundamental period of the structure, to be determined as follows
              T  =  long-period transition period (seconds) as given in Figs. 22-15 to 22-20 of

               L
                  ASCE 7-05

              S  =  the mapped maximum considered earthquake spectral parameter at a period
               1
                  of 1 s as given Figs. 22-2, 22-4, 22-6, 22-8, 22-10, 22-12, and 22-14 of
                  ASCE 7-05
           The design spectral parameters S  and S  are determined from the Eqs. (7.55) and (7.56):
                                 DS
                                       D1
                                    S  =  /3(S )                     (7.55)
                                        2
                                     DS    MS
                                        2
                                    S  =  /3(S )                     (7.56)
                                           M1
                                     D1
   475   476   477   478   479   480   481   482   483   484   485