Page 207 - Design of Solar Thermal Power Plants
P. 207
3.3 THERMAL PERFORMANCE OF PARABOLIC TROUGH COLLECTOR 191
Error/% 1.82 1.16 1.72 0.87
Value Thermal Efficiency Calculated on Measured Value/%
Calculated Based 30.45 36.92 30.55 25.38
Respective Model- Predicted Thermal Efficiency/%
and 32.27 35.75 28.83 24.51
Value
Measured Solar Energy/ MJ 1296.9 1006.4 676.18 783.57
Experiment Calculated on Measured Value/MJ
and Output Energy Based 394.92 371.56 206.58 198.88
Model
Test Predicted Energy/MJ
Dynamic Model- Output 418.56 359.84 194.94 192.03
of
Value 10:09e12:47 12:11e13:01 10:32e11:32 10:09e5:21
Predicted Time
3.8
TABLE Experimental Condition 1 2 3 4