Page 207 - Design of Solar Thermal Power Plants
P. 207

3.3 THERMAL PERFORMANCE OF PARABOLIC TROUGH COLLECTOR  191



                                            Error/%  1.82   1.16   1.72   0.87





                              Value  Thermal  Efficiency  Calculated  on  Measured  Value/%

                              Calculated  Based  30.45  36.92  30.55  25.38



                              Respective  Model-  Predicted  Thermal  Efficiency/%



                              and              32.27  35.75  28.83  24.51
                              Value

                              Measured  Solar  Energy/  MJ  1296.9  1006.4  676.18  783.57



                              Experiment  Calculated  on  Measured  Value/MJ




                              and  Output  Energy  Based  394.92  371.56  206.58  198.88
                              Model

                              Test      Predicted  Energy/MJ
                              Dynamic  Model-  Output  418.56  359.84  194.94  192.03



                              of
                              Value            10:09e12:47  12:11e13:01  10:32e11:32  10:09e5:21

                              Predicted     Time



                              3.8
                              TABLE       Experimental  Condition  1  2  3  4
   202   203   204   205   206   207   208   209   210   211   212