Page 109 - Estimators Piping Man Hour Manual
P. 109

92   Section Two-FIELD FABRICATION

                        GENERAL WELDING NOTES


      Backing Rings:  When backing rings are used, add 25% to the welding man hours to cover extra problems in fit-up.
        In addition  the following percentages should be added if applicable.
         1) When backing rings are tack welded in on one side, add 10% to the man hours of a standard thickness butt
           weld.
         2) When  backing rings are  completely  welded  in  on one side,  add  30% to the  man  hours of a standard
           thickness butt weld.
         3) Preheating and stress relieving, when required, should be charged at full butt weld preheating and stress
           relieving man hours for the size and thickness in which the backing ring is installed.
     Nozzle  Welds:  Following percentage increases should be allowed for the following  conditions:
         1) When nozzle welds are to be located off-center of the run (except tangential) increase man hours shown for
           nozzle welds, 50%.
         2) Add 80% to nozzle welds for tangential nozzle welds.
         3) When nozzle welds are to be located  on a fitting increase nozzle weld man hours 50%.
     Long-neck Nozzle  Welds:  The welding-on of long neck nozzles should be charged  at  the  schedule  160 reinforced
        nozzle weld man hours.

      Shaped  Nozzles, Nozzle  Weld  fit-ups  and Dummy  Nozzle  Welds:  These should be charged  at  a percentage of the
        completed nozzle weld man hours as follows:
         1) Shaped branch                                                  50%
         2) Shaped hole in header                                          50%
         3) Fit-up of both branch or header (whether  tack-welded  or not)  60%
         4) Dummy nozzle weld (no holes in header)                         70%
      Sloping Lines: Add 100% to all welding man hours for this condition.

      Consumable Inserts: When consumable inserts are used, add the following percentages to the welding man hours
        to cover extra problems in fit-up:
                      1) Through  1/2" wall               40%
                      2) Over l/2"through 1"wall          30%
                      3) Over l"through 2"wall            20%
                      4) Over 2" through 3" wall          15%
                      5) Over 3" wall                     10%
   104   105   106   107   108   109   110   111   112   113   114