Page 44 - Estimators Piping Man Hour Manual
P. 44

Section  One-SHOP FABRICATION    27

                 90° WELDED NOZZLES—REINFORCED
                               Labor For Cutting and Welding
                                  Carbon Steel Material
                                NET MAN HOURS EACH
           Standard  Extra
             Pipe  Heavy Pipe               SCHEDULE  NUMBERS
     Size  &OD Sizes &  OD Sizes
      Ins.  3/8"  Thick 1/2"  Thick  20  30  40  60  80  100   120   140  160
     1-1/2   4.4      4.7    --    —     4.4  ..    4.7   --   _.    --   6.7
     2       4.6       5.1   --    --    4.6        5.1   --   --          8.6
     2-1/2   5.0      6.1                5.0  --    6.1              ..    9.4
     3        5.8     6.9    __    __    5.8        6.9   __   --    --   10.4
     3-1/2   6.5       7.6               6.5  ..    7.6
     4       7.0       8.7   --          7.0  --    8.7   --  10.9        13.3
                             __    —                      __         —
     5       8.5      10.3         --    8.5  --   10.3       13.1        16.0
     6       8.9      11.1               8.9       11.1       16.1        20.1
     8       9.9      12.3   9.9   9.9   9.9  11.3  12.3  16.8  20. 8  1 24.8  27.8
     10      10.8     13.8   10.8  10.8  10.8  13.8  17.1 ...22.1  126.3  29.5  33.1
                                                        ^**mmm^f
     12      12.0     15.5   12.0  12.0  13.0  17.2  22.3  30.1  33.5  37.8  40,4
     14  OD  13.6     17.5   13.6  13.6  15.1  20.6  29.2  37.3  39.7  44.6  51.3
     16  OD  15.2     19.7   15.2  15.2  19.3  25.5  34.0  46.4  48.7  51.4  59.3
     18  OD  16.2     20.2   16.2  18.7  23.7  31.7  38.1  50.4  52.4  55.4  74.2
     20 OD   17.9     22.5   17.9  22.4  27.4  40.0  47.0  54.0  62.5  71.8  83.3
     24  OD  18.9     23.5   18.9  25.7  30.9  44.5  50,4  61.3  72.6  84.0  97.4

        All Nozzles  other than 90° should  be charged  at  the man hours shown for  45° nozzles.

     Pipe  Thickness:  Wall  thickness  of  the  pipe used for  the nozzle determines  the man hours  that
        will  apply.  For  nozzles of double extra  strong pipe thickness, use Schedule  160 man hours.
     Reinforcement:  Man hours are  for  labor  only.  The price  of the nozzle and reinforcing  materials
        must be added.
     Preheating;  If  specified  or  required  by Codes, add for this  operation.  See man hours  for  pre-
        heating.  The  size  and  wall  thickness of header  (not the size of the nozzle) determines the
        preheating man hours.
     Stress  Relieving:  Stress  relieving  of welds in carbon steel material is  required by the A.S. A.
        Code  for  Pressure  Piping, where the wall thickness  is  3/4"  or greater.  The size  and wall
        thickness of the header determines  the  man hours to be used for stress  relieving.
        All  pipe  sizes  shown  below  the  ruled line are  3/4"  or  greater  in wall thickness  and must
        be stress relieved.  Where  stress  relieving  is  required  an  extra  charge  should be made.
        See man hours for stress  relieving.

     For  General  Nolex  on  welding,  see pages  20 and  23.
   39   40   41   42   43   44   45   46   47   48   49