Page 335 - Finite Element Modeling and Simulations with ANSYS Workbench
P. 335

320                   Finite Element Modeling and Simulation with ANSYS Workbench



                   Step 2: Add Material Properties
                   Double-click  on  Engineering  Data  of  Steady-State  Thermal.  Add  a  Density
                                3
                     of  2800 kg/m , change the  Unit to ‘JKg^-1K^-1’ and enter  Specific Heat of
                     870 J/ (kg ⋅ K) to the Properties of Aluminum. Close the  A2,B2:Engineering
                     Data interface.
































                   Step 3: Set Up Transient Thermal Analysis
                   Double-click on the Setup cell of the Transient Thermal system to launch the
                     Multiple Systems–Mechanical program. Click Yes on the pop-up window to
                     read the modified upstream data.












                   Select Analysis Settings from the Project Outline. In the Details of “Analysis
                     Settings”, under Step Controls, set the Step End Time to 180s. Change the
                     Auto Time Stepping to On from Program Controlled. Change Defined By to
                     Time. The default values for the initial and the maximum time steps are small
                     for this model. Set the Initial Time Step to 0.1. Set the Minimum Time Step to
                     0.05. Set the Maximum Time Step to 5. A small time step will help increase the
                     accuracy of the model and also produce enough result steps so the animation
                     will have smooth transition between solution steps.
   330   331   332   333   334   335   336   337   338   339   340