322                   Finite Element Modeling and Simulation with ANSYS Workbench



                   Click on Tabular Data on the right edge of the Graphics window, and then click
                     on the push pin labeled AutoHide to display the Tabular Data window as
                     shown below. Enter the following values in the Tabular Data table.





























                   Step 5: Apply Convective Boundary Condition
                   Right-click on Transient Thermal (B5). Choose Insert and then Convection from
                     the context menu. In the  Details of “Convection”, enter  30 W/(m  ⋅ °C) for
                                                                            2
                     Film Coefficient and 28°C for Ambient Temperature to all surfaces (a total of
                     29 faces) except for the base of the heat sink.
   332   333   334   335   336   337   338   339   340   341   342