Page 341 - Finite Element Modeling and Simulations with ANSYS Workbench
P. 341

326                   Finite Element Modeling and Simulation with ANSYS Workbench



                   Step 2: Add Material Properties
                   Double-click Engineering Data of Steady-State Thermal. Add Young’s Modulus
                     of 70 GPa, Poisson’s ratio of 0.3 and Isotropic Instantaneous Coefficient of
                     Thermal Expansion of 2.2E-5 1/°C to the Properties of Aluminum as shown
                     below. Close the A2,B2,C2:Engineering Data interface.


































                   Step 3: Set Up Static Structural Analysis
                   Double-click on the  Setup cell of the  Static Structural system to launch the
                     Multiple Systems–Mechanical program. Click Yes on the pop-up window to
                     read the modified upstream data.














                   Note an Imported Load item is automatically added to Static Structural (C5)
                     in the Outline tree. Right-click on Static Structural (C5) and insert a Fixed
                     Support to the Outline. Apply the fixed support to the bottom face of the heat
                     sink.
   336   337   338   339   340   341   342   343   344   345   346