Page 343 - Finite Element Modeling and Simulations with ANSYS Workbench
P. 343
328 Finite Element Modeling and Simulation with ANSYS Workbench
Click on Equivalent Stress in the Outline to review von Mises stress results.
Modeling tips: To apply a uniform temperature load to the heat sink, you may
add a Static Structural system that shares data with Steady-State Thermal
system at the model and above levels. And then insert a constant Thermal
Condition load to the heat sink in the Static Structural analysis.
To do this, first drag the Static Structural icon from the Analysis Systems
Toolbox window and drop it onto the Model cell of the highlighted Steady-
State system in the Project Schematic.