FLOW MEASUREMENT
            76
                  plugging, to protect the cleanliness of optical de-  . “ Pressure drop in a rotameter is constant” True/False?
                  vices, and to protect electrical devices from igniting  & True. Pressure drop (head) will be constant across the
                  upon contact with combustibles.                      float only if flow area remains constant.
                 & Purge meters are quite useful in adding nitrogen gas  . “A rotameter must not constrict flow.” True/False?
                  to the vapor spaces of tanks and other equipment.  & True.
                  Purging with nitrogen gas reduces the possibility of
                                                                   . What are the disadvantages of a rotameter?
                  developing a flammable mixture because it displaces
                                                                     & Glass is breakable which could lead to hazardous
                  flammable gases.
                                                                       situations when handling toxic or flammable liquids.
                 & The purge flow regulator is reliable, intrinsically safe
                                                                     & With opaque or cloudy liquids, float will not be
                  and inexpensive.
                                                                       visible (special rotameters are available, which are
                 & Figure 4.20 illustrates its working:
                                                                       more expensive).
               . What is the difference between correlated and direct
                                                                     & No output for data transmission.
                reading rotameters?
                                                                     & Sensitive to differing gas types and changes in tem-
                 & A direct reading flow meter indicates the flow rate on
                                                                       perature and pressure. In other words, as these meters
                  its scale in specific engineering units (e.g., mL/min or
                                                                       measure volumetric flow rates, gas density variations
                  scf/h). Direct reading scales are designed for a spe-
                                                                       will affect measurements.
                  cific gas or liquid at a given temperature and pressure.
                                                                     & DP is high.
                  While it is more convenient than a correlated flow
                  meter, a direct reading flow meter is less accurate and  & Accuracy is only 2–3% unless expensive high pre-
                  limited in its applications.                         cision rotameter is employed.
                 & Acorrelatedflowmeterisscaledalongeithera65 mm      & Not suitable for high capacities.
                  or a 150 mm length, from which a reading is taken.  & Accumulation of dirt or other foreign matter depos-
                  The reading is then compared to a correlation table  ited on the float or tube walls can cause wrong
                  for a specific gas or liquid. This will give the actual  readings.
                  flow in engineering units. One correlated flow meter  . What type of rotameter is used for opaque or cloudy
                  can be used with a variety of fluids or gases.      liquids?






































                                               FIGURE 4.20 Purge flow meter design.