DESIGN ERRORS, CONSTRUCTION DEFECTS, AND PROJECT MISCOMMUNICATION  8.19























                     FIGURE 8.12  Markings on wood components and fastener size verification
                     gauge.
              of the size and location of other hardware and connectors to ensure a continuous load path
              to the foundation is also needed. For example, the edge distance of the anchor bolts in
              Fig. 8.13 demonstrates this construction defect.
             • Wood framing for panelized roof assemblies in large buildings, even of masonry and con-
              crete construction is a frequently used construction method. Extremes of moisture content
              in wood framing members can result in loss of strength; consequently it is imperative to





























                              FIGURE 8.13 Inadequate edge distance between
                              anchor bolt and edge of wood sill plate.