Page 136 - Formulas and Calculations for Petroleum Engineering
P. 136

Drilling engineering formulas and calculations Chapter  2  129



             2.127 Lateral load imposed on a casing centralizer—Cementing

             Input(s)
                m:   Steel in Mud Buoyancy Factor (dimensionless)
                W:   Weight per foot of Casing (lbm)
                L:   Distance from Centralizer to next Lower Centralizer (ft)
                y:   Borehole Angle (degree)
                T:   Tension (Pulling Force) due to casing below Centralizer (lbm)
                d:   One-half the change in Angle between Centralizer and next Lower Centralizer (degrees)


             Output(s)
                F L :  Lateral Load, Casing Weight Component   Tension Component (lbm)


             Formula(s)

                                                   L
                                                 F ¼ m W  L  siny 2 TðÞsind
             Reference: Suman Jr, G. O., & Ellis, R. C. (1977). Cementing handbook. World Oil, Page: 44.


             2.128 Lateral load imposed on a casing centralizer with a dogleg—Cementing
             Input(s)

                m:   Steel in Mud Buoyancy Factor (dimensionless)
                W:   Weight per foot of Casing (lbm)
                L:   Distance from Centralizer to next Lower Centralizer (ft)
                y:   Borehole Angle (degree)
                T:   Tension (Pulling Force) due to casing below Centralizer (lbm)
                d:   One-half the change in Angle between Centralizer and next Lower Centralizer (degrees/100 ft)


             Output(s)
             F L :  Lateral Load, Casing Weight Component   Tension Component (lbm)


             Formula(s)


                                                   L
                                                 F ¼ m W  L  siny 2 TðÞsind
                                                          degrees

                                                   Dogleg          Spacing ftðÞ
                                                           100ft
                                                d ¼
                                                              200
                                                        X
                                                     T ¼   m W  L  cosy
             Reference: Suman Jr, G. O., & Ellis, R. C. (1977). Cementing handbook. World Oil, Page: 44.

             2.129 Linear annular capacity of pipe

             Input(s)
                D h :  Inside Diameter of Casing Against the Pipe (in.)
                D o :  Outside Diameter of Pipe (in.)
   131   132   133   134   135   136   137   138   139   140   141