Page 173 - Fundamentals of Magnetic Thermonuclear Reactor Design
P. 173

154     Fundamentals of Magnetic Thermonuclear Reactor Design

























































            FIGURE 5.29  The SULTAN test facility.


            the cryostat and the shields are at the same potential. Still, high-voltage tests,
            performed at the Paschen minimum, can be regarded as an important part of a
            procedure used to monitor the electrical insulation at different stages of coil
            manufacturing.
               The ITER coils’ electrical strength is provided by the hard turn and ground
            insulation. That is why the comparison of different insulation technical options