Page 230 - Fundamentals of Magnetic Thermonuclear Reactor Design
P. 230

(Continued)
                                                400/3000
                                                        10 −3 /300
                                                                   <1(Cu)
                                                              ∼10
                                                                50
                                                  —
                                                           —
                                                     —
                TABLE 7.1 Expected Operating Conditions of the ITER In-Chamber Components (EDA Phase, 2001)
                                                400/3000
                                                        10 −3 /300
                                                     0.2/150
                                                                   <1(Cu)
                                                  1/3000
                                                              ∼20
                                                                150
                                                           —
                                                400/3000
                                                           10 −2 /300
                                                        10 −3 /300
                                                              100–136
                                                                   <1(Cu)
                                                  10/300
                                                                50
                                                     —
                      Start-up limiter Baffle (the upper part of   Divertor   Divertor liner the divertor vertical target) vertical target  6  5  4  3  <1  1–3(5)  10  0.5  —  20  4–8  —  60  —  —  1–3  1  12  1  —  —  25  —  First Wall Components  Chapter | 7    213
                                                        10 −3 /3000
                                                400/3000
                                                  30/6000
                                                                   1.6 (Be)
                                                                     5.3 (Cu)
                                                                       2.7 (SS)
                                                              15
                                                     —
                                                                7
                      First wall  2  0.5  —  60  0.36  —  400/3000  —  0.2/150  10 −3 /3000  170  680  1.6 (Be)  5.3 (Cu)  2.7 (SS)
                      Operation conditions  1  Peak heat load    Quasi-stationary (MW/m 2 )    Transient (MW/m 2 )   Vertical displacement (MJ/m 2 )   Plasma current disruption (MJ/m 2 )    ‘Runaway’ electrons (MJ/m 2 ) Pulse length(s)/number of heat pulses during    A quasi-stationary load    Transient conditions    Vertical displacement
   225   226   227   228   229   230   231   232   233   234   235