Page 480 - Fundamentals of Water Treatment Unit Processes : Physical, Chemical, and Biological
P. 480

Cake Filtration                                                                                  435



                                                           W(pre-coat)  (kg=m 2 )  (lb=ft 2 )  0.73  0.15       (continued)







                                                           feed)  (kg=m 3 )  0.025


                              7.15E 09                 Conditions  C(body  (mg=L)  25
                        M5

                                                                (m=s)  0.001408



                        M4     1.188E 06                   HLR  (m=h)  3.66


                  14.8                                          (gpm=ft 2 )  1.50

                  Equation  M3   7.54E 09  0.00010295           m=r w (g)  1.32E 07



                  by  Dependence
                  Calculated  M2  1.00E 06   0.0091438  T 6    M6  14-*)  Water  m  (N-s=m 2 )  0.00132





                  as  Temperature   þ T 5    M5     Equation  r w  (kg=m 3 )  1.00Eþ03
                  Variables  for Coefficients  M1   5.61E 05  0.068256  þ T 4    M4  by  T (8C)  10         feed)   v   t




                  Hydraulic         þ T 3    M3     (Calculated                                               k(cake)   r(cake)



                  of    M0  0.001787  999.84  650  9.806  þ T 2     Variables  k(cake)  (m 2 )  1.08570E 12  6.90900E 14  1.57920E 13  5.92200E 14  2.46750E 13  4.93500E 13  1.08570E 12  1.28310E 12  1.87530E 12  2.96100E 12  3.94800E 12  7.30380E 12  2.46750E 11
                  Function          M2  þ T                     (Darcys)  1.10  0.07  0.16  0.06  0.25  0.50  1.10  1.3  1.9  3.0  4.0  7.4  25.0  k(pre-coat)   r(pre-coat) þ C(body



                  a        s=m 2 )    M1            Hydraulic                                              W(pre-coat)
                  as    Units    (N  (kg=m 3 )  (m=s 2 )  þ
               CD14.2  Loss         M0  ¼ y         of  Properties  r(body  feed)  (kg=m 3 )  144  112  128  128  128  128  144  152  152  192  192  228  312     m  v r w g


               TABLE  Pressure  Variable  m(water)  r(water)  Formula:  Function  DE  r  (pre-coat)  (kg=m 3 )  144  112  128  128  128  128  144  152  152  192  192  228  312  ¼ h L

                                G
                                                    as
                                                    Calculations  r(Dry  Density)  (kg=m 3 )  144  112  128  128  128  128  144  152  152  192  192  228  312


                                                 CD14-*         DE  Super-  data         Super-



                                                 TABLE  Headloss  of  Grade  Hyflo  Cel  Reference  Cel  Filter  577  Celite  505  Celite  Standard  Super-Cel  512  Celite  Hyflo  Cel  501  Celite  503  Celite  535  Celite  545  Celite  550  Celite  560  Celite
   475   476   477   478   479   480   481   482   483   484   485