Page 111 - Handbook of Civil Engineering Calculations, Second Edition
P. 111

1.94            STRUCTURAL STEEL ENGINEERING AND DESIGN

                            9. Calculate the axial force in the cover plate
                            Calculate the axial force P lb (N) in the cover plate at its end by computing the mean
                            bending stress. Determine the length of fillet weld required to transmit this force to the W
                            shape. Thus f mean   My/I   215,600(12)(9.31)/1634   14,740 lb/sq.in. (101,632.3 kPa).
                                                                             1
                            Then P   Af mean   3.75(14,740)   55,280 lb (245,885.4 N). Use a  /4-in. (6.35-mm) fil-
                            let weld, which satisfies the requirements of the Specification. The capacity of the weld
                            4(600)   2400 lb/lin in. (420,304.3 N/m). Then the length L required for this weld is L
                            55,280/2400   23.0 in. (584.20 mm).
                            10. Extend the cover plates
                            In accordance with the Specification, extend the cover plates 20 in. (508.0 mm) beyond
                                                                           1
                            the theoretical cutoff point at each end, and supply a continuous  /4-in. fillet weld along
                            both edges in this extension. This requirement yields 40 in. (1016.0 mm) of weld as com-
                            pared with the 23 in. (584.2 mm) needed to develop the plate.
                            11. Calculate the horizontal shear flow at the inner surface
                            of the cover plate
                            Choose F or G, whichever is larger. Design the intermittent fillet weld to resist this shear
                            flow. Thus V F   35.2 – 8 – 1.2(8.25)   17.3 kips (76.95 kN); V G   –30.8 + 1.2(8.36)
                            –20.8 kips (–92.51 kN). Then  q   VQ/I   20,800(3.75)(9.31)/1634    444 lb/lin in.
                            (77,756.3 N/m).
                              The Specification calls for a minimum weld length of 1.5 in. (38.10 mm). Let s denote
                            the center-to-center spacing as governed by shear. Then s   2(1.5)(2400)/444   16.2 in.
                            (411.48 mm). However, the  Specification imposes additional restrictions on the weld
                            spacing. To preclude the possibility of error in fabrication, provide an identical spacing at
                            the top and bottom. Thus, s max   21(0.375)   7.9 in. (200.66 mm). Therefore, use a  /4-
                                                                                          1
                            in. (6.35-mm) fillet weld, 1.5 in. (38.10 mm) long, 8 in. (203.2 mm) on centers, as shown
                            in Fig. 4a.


                            DESIGN OF A CONTINUOUS BEAM

                            The beam in Fig. 5a is continuous from A to D and is laterally supported at 5-ft (1.5-m)
                            intervals. Design the member.

                            Calculation Procedure:

                            1. Find the bending moments at the interior supports; calculate
                            the reactions and construct shear and bending-moment diagrams
                            The maximum moments are +101.7 ft·kips (137.9 kN·m) and –130.2 ft·kips (176.55
                            kN·m).
                            2. Calculate the modified maximum moments
                            Calculate these moments in the manner prescribed in the AISC Specification. The clause
                            covering this calculation is based on the postelastic behavior of a continuous beam. (Refer
                            to a later calculation procedure for an analysis of this behavior.)
                              Modified maximum moments: +101.7 + 0.1(0.5)(115.9 + 130.2)    +114.0 ft·kips
                            (154.58 kN·m); 0.9(–130.2)   –117.2 ft·kips (–158.92 kN·m); design moment   117.2
                            ft·kips (158.92 kN·m).
                            3. Select the beam size
                                                                  3
                                                         3
                            Thus, S   M/f   117.2(12)/24   58.6 in (960.45 cm ). Use W16   40 with S   64.4 in 3
                                     3
                            (1055.52 cm ); L c   7.6 ft (2.32 m).