STRUCTURAL STEEL DESIGN               1.157

                              The modified modulus of elasticity for composite design is
                                                                        28.9 sq.in.
                                            E m   29,000 ksi + 0.4   3267 ksi
                                                                        5.6 sq.in.
                                                  35,744 ksi (246,276 MPa)

                              The radius of gyration of a hollow circular shape
                                                D  +  D  i   2
                                                  2
                                           r              (See AISC LRFD Manual, p. 7-21.)
                                                  4













                                              (6.625 in.)  +  (6.065 in.)  2
                                                       2
                                                                    2.25 in. (5.72 cm)
                                                       4
                              for the bare steel pipe.
                                The modified radius of gyration for composite design
                                                 r m   r   0.3D (the overall dimension)
                                                     2.25 in.   (0.3   6.625 in.   1.99 in.)
                                                     2.25 in. (5.72 cm)
                              The slenderness parameter
                                                     Kl
                                                           F my
                                                  c
                                                     r m
                                                            E m
                                                    10.0 ft × 12 in./ft  51.4 ksi
                                                                  	           0.64

                                                      2.25 in. ×    35,744 ksi
                              Because   c < 1.5
                                                       2
                                            F cr   (0.658 c)F my
                                                 0.658 (0.64) 2    51.4 ksi   43.2 ksi (297.6 MMPa)
                              The design compressive strength
                                                c P n     c A s F cr
                                                   0.85   5.6 sq.in.   43.2 kips/sq.in.
                                                   205 kips > 200 kips required
                                c P n   205 kips (911.8 kN) for this case is also tabulated on p. 4-100 of the AISC LRFD
                              Manual.
                                The 6-in. (15.2 cm) standard-weight concrete-filled pipe-column is satisfactory.
                              Related Calculations. This procedure is the work of Abraham J. Rokach, MSCE, As-
                              sociate Director of Education, American Institute of Steel Construction. SI values were
                              prepared by the handbook editor.