Design of Connections for Axial, Moment, and Shear Forces

                            Design of Connections for Axial, Moment, and Shear Forces  49

                    3. Gusset-to-beam: The loads are 627 kips shear and 168 kips axial.
                       The length of the gusset is 52.25 in. The 1-in snip can be ignored with
                       negligible effect on the stress.
                       a. Gusset stresses:
                                 627
                        f 5              5 16.3 ksi  , 1.0 3 0.6 3 36 5 21.6 ksi, ok
                         v
                             0.75 3 51.25
                                 168
                          5              5 4.37 ksi , 0.9 3 36 5 32.4 ksi, ok
                        f a
                            0.75 3 51.25
                       b. Weld of gusset to beam bottom flange: The resultant force per inch
                         of weld is

                                                       0.75
                                                   2
                                           2
                                 f 5 216.3 1 4.37 3         5 6.33 kips in
                                  r
                                                        2
                         To account for the directional strength increase on fillet welds
                                        4.37
                                     21
                               5  tan  a    b 5 15.08
                                        16.3
                                             1.5                1.5
                               5 1.0 1 0.5 sin    5 1.0 1 0.5 sin   s15d 5 1.07
                         The required weld size is
                                              6.33
                                     D 5               3 1.25 5 5.31
                                          1.392 3 1.07
                         which indicates that a 3/8-in fillet weld is required. The factor 1.25
                         is a ductility factor from the work of Richard (1986) as modified by
                         Hewitt and Thornton (2004). Even though the stress in this weld
                         is calculated as being uniform, it is well known that there will be
                         local peak stresses, especially in the area where the brace-to-gusset
                         connection comes close to the gusset-to-beam weld. An indication
                         of high stress in this area is also indicated by the Whitmore sec-
                         tion cutting into the beam web. Also, as discussed later, frame
                         action will give rise to distortional forces that modify the force dis-
                         tribution given by the UFM.
                       c. Checks on the beam web: The 627-kip shear is passed into the
                         beam through the gusset-to-beam weld. All of this load is ulti-
                         mately distributed over the full cross-section of the W14   82, 411
                         kips passes to the right, and 216 kips are transferred across the
                         column. The length of web required to transmit 627 kips of shear
                         is l  , where 627   1.0   .6   50   .510   l  . Thus
                            web                                   web
                                                 627
                                   l web 5                    5 41.0 in
                                         1.0 3 0.6 3 50 3 0.51