Design of Connections for Axial, Moment, and Shear Forces

                    50    Chapter Two

                        which is reasonable. Note that this length can be longer than the
                        gusset-to-beam weld, but probably should not exceed about half the
                        beam span.
                         The vertical component can cause beam web yielding and crippling.
                         (1) Web yielding: The web yield design strength is

                      R     1   0.51   50(51.25   2.5   1.45)   1400 kips >168 kips, ok
                        wy
                         (2) Web crippling: The web crippling design strength is
                                                       N    t w  1.5  EF t
                                                                       y f
                                               2
                          R wcp  5 0.75 3 0.8 3 t w c1 1 3a ba  b  d
                                                        d   t f   B t w
                                                           51.25   0.51  1.5
                                                   2
                               5 0.75 3 0.8 3 0.510 c1 1 3a     ba      b  d
                                                            14.3   0.855
                                     29,000 3 50 3 0.855
                                 3                           5 1450 kips . 168 kips, ok
                                   B         0.51
                             The above two checks on the beam web seldom control but should
                             be checked “just in case.” The web crippling formula used is that
                             for locations not near the beam end because the beam-to-column
                             connection will effectively prevent crippling near the beam end.
                             The physical situation is closer to that at some distance from the
                             beam end rather than that at the beam end.
                    4. Beam to column: The loads are 216 kips axial, the specified transfer
                       force and a shear which is the sum of the nominal minimum beam
                       shear of 10 kips and the vertical force from the gusset-to-beam con-
                       nection of 168 kips. Thus, the total shear is 10   168   178 kips.
                       a. Bolts and end plate: As established earlier in this example, the bolt
                         design strength in shear is  r    31.6 kips. In this connection,
                                                     str
                         since the bolts also see a tensile load, there is an interaction
                         between tension and shear that must be satisfied. If V is the fac-
                         tored shear per bolt, the design tensile strength is
                                                       V
                                     r  5 1.13T a1 2      b # 0.75 3 90A b
                                       t
                                                b
                                                       r str
                         This formula is obtained by inverting Specification formula J3-5a.
                                                                   1
                         T is the bolt pretension of 56 kips for A325 1 / -in-diameter bolts
                           b                                        8
                                                                              2
                                                                   2
                         and A is the bolt nominal area    /4 3 1.125 5 0.994 in .
                               b
                         For V   179/10   17.9 kips   31.6 kips, ok,
                          r  5 1.13 3 56s1 2 17.9/31.6d 5 27.4 kips  and 0.75  90  .994
                            t
                         67.1 kips.
                         Thus  rr 5 27.4  kips and  R   10   27.4   274 kips > 216 kips,
                                 t
                                                    t
                         ok. Checking the interaction for an N-type bearing connection,
                 Downloaded from Digital Engineering Library @ McGraw-Hill (www.accessengineeringlibrary.com)