Page 110 - Hybrid-Renewable Energy Systems in Microgrids
P. 110

94                                  Hybrid-Renewable Energy Systems in Microgrids

          Table 5.4  A Comparison Between Characteristics of the Hybrid
          Topologies
           Topology in single
           phase                #1    #2    #3       #4       #5      #6
           Number of          N − 1 N − 1 N − 1     N − 3    N − 1  (5N − 3)/6
            semiconductor switches
            in the level generation
            part versus output
            voltage levels (N)
           Number of            2    V DC    1        2       V DC    V DC
            semiconductor
            switches in the level
            generation part that
            are in the current path
            to produce maximum
            output voltage versus
            DC sources (V DC )
           Maximum blocking     2     2    n.V DC (n − 1) V DC /2 2. V DC  3. V DC
            voltage for switches in
            level generation part






























         Figure 5.13  Number of switches in level generation part for single phase hybrid
         multilevel inverters.