Page 378 - Introduction to Marine Engineering
P. 378

348  Watchkeeping and equipment  operation

                  1.  Emergency generator  should  be  started  and  run  for  a  reasonable
                     period. Fuel oil, lubricating oil and cooling water supplies and tank
                     levels should  be  checked.
                  2.  Emergency  fire  pump  should  be  run  and  the  deck  fire  main
                     operated  for  a reasonable period.  AH operating  parameters should
                     be checked.
                  3.  Carbon dioxide cylinder storage  room  should be visually examined.
                     The  release box door should be opened to test the alarm and check
                     that the  machinery-space fans  stop.
                  4.  One  smoke  detector  in  each  circuit  should  be  tested  to  ensure
                     operation  and  correct  indication on  the  alarm  panel.  Aerosol  test
                     sprays are  available to  safely  check some types of  detector.
                  5.  Fire  pushbutton  alarms  should  be tested,  by operating  a  different
                     one during  each test.
                  6.  Any  machinery space  ventilators or  skylights  should  be  operated
                     and  greased,  if  necessary, to  ensure  smooth, rapid  closing should
                     this be necessary.
                  7.  Fire extinguishers  should  be observed  in their  correct location  and
                     checked  to ensure  they are  operable.
                  8.  Fire  hoses and  nozzles should  likewise be  observed  in their  correct
                     places.  The  nozzles  should  be  tried  on  the  hose  coupling.  Any
                     defective  hose  should be  replaced.
                  9.  Any emergency  batteries,  e.g.  for  lighting or  emergency  generator
                     starting, should be examined, have the acid specific gravity checked,
                     and  be topped  up,  as  required.
                 10.  All lifeboat engines should be  run  for  a reasonable period.  Fuel oil
                     and  lubricating oil levels should  be checked.
                 11.  All  valves  and  equipment  operated  from  the  fire  control  point
                     should  be checked  for  operation,  where this is possible.
                 12.  Any watertight  doors  should  be  opened  and  closed  by hand  and
                     power. The  guides should be checked  to ensure that they are clear
                     and  unobstructed.
   373   374   375   376   377   378   379   380   381   382   383