            Source of Problem            Suggested CauselRemedy
         8.  System problem.             Wrong rotation
         9.  System problem.             Low speed
        IO.  System problem.             Insufficient liquid supply
        11.  System problem.             Excessive discharge pressu relresista nce

        12.  System problem.             Grit or dirt in liquid.
        13.  System problem.             Pump running dry
        14.  System problem.            Viscosity  of  liquid  being  pumped  is  higher
                                         than specified.
        15.  System problem.             Obstruction in the discharge line
        16.  Mechanical problems.        Unbalanced or misaligned coupling.
        17.  Mechanical problems.        Bent motor shaft

        18.  Mechanical problems.        Chattering relief valve
        19.  Mechanical problems.        Pipe strain distorting the pump casing.
        20.  Mechanical problems.       Air aspiration thru the packing/seal.
        21.  Mechanical problems.        Inadequate relief valve.
        22.  Mechanical problems.        Packing is too tight.

        23.  Mechanical problems.        Corrosion.



      I     Oh yes, 'Comm  on Sense Maintenance' is likely to be the title of our next book.