Page 238 - Lindens Handbook of Batteries
P. 238

9.32        PRIMARY BATTERIES


                                       6.0
                                                              2 h/day                     10.0
                                                              4 h/day
                                       4.0                    8 h/day                     6.0
                                                                                          4.0
                                       2.0
                                    Amperes/kilogram  1.0                                 2.0  Amperes/liter


                                                                                          1.0
                                       0.6
                                                                                          0.6
                                       0.4
                                                                                          0.4
                                       0.2
                                                                                          0.2
                                       0.1
                                     0.060                                                0.1
                                               6   10    20   4060   100   200   400 600 1000
                                                             Hours of service
                                   FIGURE 9.31  Service hours for a general-purpose zinc-carbon battery discharged intermittently
                                   to 0.9 V at 20°C.



                             TABLE 9.8  Manufacturer’s Data for AA-Size Zinc-Carbon Batteries

                                                                             Cutoff Voltage V
                                               Drain @
                                 Schedule      1.2 V, mA  Load Ω  1.3   1.2    1.1   1.0   0.9   0.8
                                            Typical service of Eveready No. 1015 general-purpose battery
                                                                                Hours
                             4 h/day            28 mA     43     2      5     12    20    24     27
                             1 h/day           120 mA     10     0.1    0.4    1.2   2.6   3.9   4.5
                             1 h/day           308 mA      3.9   0.09   0.2    0.4   0.7   0.9   1.0
                                                                                Pulses
                             15 s/min/24 h/day    667 mA   1.8   6      14    30    51    68     73
                               (pulse)
                                            Typical service of Eveready No. 1215 super heavy-duty battery
                                                                                Hours
                             4 h /day           28 mA     43     4      10    21    31    36     39
                             1 h /day          120 mA     10     0.2    0.4    2.5   5.2   6.4   7.0
                             1 h /day          308 mA      3.9   0.1    0.3    0.5   1.2   1.7   1.9
                                                                                Pulses
                             15 s/min/24 h/day    667 mA   1.8   7      14    30    89    139   160
                               (pulse)
                                Source:  Eveready Battery Engineering Data. 12
   233   234   235   236   237   238   239   240   241   242   243