Page 371 - Lindens Handbook of Batteries
P. 371

3.6
                                     3.5                                      +70°C
                                     3.4                                            +55°C
                                  Cell voltage, V  3.2                      –20°C       +20°C
                                     3.3

                                     3.1
                                     3.0
                                     2.9
                                     2.8
                                                                            –40°C
                                     2.7
                                       1             10           100           1000         10000
                                                               Current, mA
                                                                  (a)
                                    15.0
                                    14.0
                                    13.0
                                    12.0
                                    11.0                                           +55°C
                                  Capacity, Ah  10.0                               +70°C  +20°C
                                     9.0
                                     8.0
                                     7.0
                                     6.0
                                     5.0
                                     4.0                                               –20°C
                                     3.0                                           –40°C
                                     2.0
                                       1             10           100           1000         10000
                                                               Current, mA
                                                                  (b)
                                 FIGURE  14.26  Discharge  characteristics  of  spirally  wound  Li/SOCl   D-size  battery,  at  various
                                                                               2
                                 temperatures. (a) Voltage vs. current. (b) Capacity vs. current. (Courtesy of SAFT Batteries.)
                 TABLE 14.12  Characteristics of Typical Cylindrical Spirally Wound Li/SOCl  Batteries
                                                                     2
                        Size          1/3 C        C        C (light)     D         D          D
                  Capacity at 20° (Ah)  1.2        5.8        3.6        13.0      12.0      14.0
                  rated current (mA)  10          15         15          15        50        300
                  Nominal voltage      3.6         3.6        3.6         3.6       3.6       3.6
                  Dimensions (max)
                    Diameter (mm)     26.2        26.0       26.0        33.4      33.4      32.05
                    Height (mm)       18.6        50.4       50.4        61.6      61.6      61.7
                  Maximum current for   0.4        1.3        1.3         1.8       1.0   Not specified
                  continuous use (A)
                  Weight (g)          24          51         51          100       100       104.5
                  Operating temperature   -60/+85  -60/+85  -60/+85     -65/+85  -65/+120  -40/+150
                  range (C)
                 Transport         Non-restricted  Class 9  Non-restricted  Class 9  Class 9  Class 9
                    Source:  SAFT Batteries.
                    Open circuit voltage = 3.67 V. individual cells fitted with non-resettable 5 Amp fuse protection.

                 14.36
   366   367   368   369   370   371   372   373   374   375   376