             After the jack screws have been removed, torque all the anchor bolts to
           their designed load. This should be the first and last time the anchor bolts
           are tightened. Check the grout job for voids by ringing the baseplate with
           a hammer (Figure 3-50). A good grout job will sound like you are hitting
           a lead plate, and voids will ring like a bell. If this procedure is followed
           to the letter, there will be no voids in the grout.