320 Machinery Component Maintenance and Repair
stalled. The operation of the instrument and the determination of the
masses required to correct the unbalance is carried out by trained person-
nel. Not only does this result in considerable cost savings but the method
also provides a significant saving in time compared to rebalancing on a
balancing machine. With careful preparation, field balancing of a blower
need not take more than 30-60 minutes.
It has been shown in practice that in over 95 percent of all blowers field
balancing in one plane is sufficient to reduce unbalance vibrations to per-
missible and safe values. The method is as follows:
1. The balancing instrument is used to measure the unbalance vibra-
tion at the bearing positions nearest to the blower rotor (Figures
6-41 and 6-42). The instrument suppresses with a high degree of
separation any extraneous vibration and shows the amount and the
angular position of the rotational frequency vibrations. Both mea-
sured values-also designated as “initial unbalance”-are entered
on a vector diagram (Figure 6-43).
Figure 6-41. Individual stages in the field balancing of a blower using balancing and vibra-
tion analyzer “VIBROTEST.”