Page 181 - Managing Global Warming
P. 181

144                                               Managing Global Warming



          Table 4.5 Basic parameters of AP-1000 US Generation III+ PWR
          NPP (Shultis and Faw [7,8])

          Parameter                                               Value
          Thermal power (MW th )                                  3415
          Electrical power (MW el )                               1110
          Thermal efficiency (%)                                  33
          Number of loops                                         2
          Hot leg temperature (°C)                                321
          No. of fuel bundles                                     157
          Type of fuel assembly                                   17 17
          Active fuel height (m)                                  4.3
                            1
          Linear heat flux (kWm )                                 18.7
          Control rod clusters assemblies                         53 (16Gy)
          Reactor vessel ID (m)                                   3.99
                            1
                        3
          Vessel flow rate (m h )                                 68,100







          Table 4.6 Main design and operating parameters for EPR (AREVA)

          Parameter                               Value
          Thermal power (MW th )                  4590
          Electrical power (MW el )               1650
          Gross thermal efficiency (%)            36–37
          No. of loops                            4
          Operating/design pressure (MPa)         15.5/17.6
          RPV inlet/outlet temperatures (°C)      295/330 (T sat @ 15.5MPa¼345°C)
                           3
          Total flow/loop rate (m h  1)           28,315
          Main steam operating/design pressure (MPa)  7.72/10

          Core
          Active height (m)                       4.2
          No. of fuel assemblies                  241
          No. of RCCAs (rod cluster control assemblies)  89
          Fuel-assembly array (bundle)            17 17
          No. of fuel rods                        63,865
                                  1
          Average linear heat flux (kWm )         16.7
          Based on data from AREVA (France) http://www.areva.com/EN/operations-5444/epr-reactor-fact-sheet.html;
          [Accessed 15 October 2017].
   176   177   178   179   180   181   182   183   184   185   186