Page 28 - Membranes for Industrial Wastewater Recovery and Re-Use
P. 28

'hble 1.5  Examples of water management, UK
 ._
 Type   Application   Scenario   Solution   Cost benefit
 Audit   Cellophane   750 m3/day of water unaccounted for   Fix leak   tlOO000p.a. saving[$l41580]*
 production
 Audit   Laboratory   Mains water used for single-pass cooling,  Fit cooler (€2000) [$2831]*   6 month payback
 12 m3/day
 Housekeeping  Resin factory   Wash water contaminated by spillages   Fit drip trays to point sources   Effluent COD reduced by 75%,
 from point sources         €3000 p.a. saving [$4217]*
 Housekeeping  Plating plant   Significant drag out of chemicals from   Improve drainage around plating bath   Reduced rinsewater contamination,
 plating bath into rinse bath   €1000 p.a. saving [$1416]*
 Reuse   Plating plant   0.4 m3/h mains water fed to three rinsing  Use counter-current serial flow to all   50% water saving, €1500 pa. [$2  241'
 baths in parallel, 1.2 m3/h In total   three baths
 Recycling   Cadmium   Zero discharge of cadmium imposed by   Installation of deionisation plant to   12 monthpayback
 plating   regulator   recover cadmium and water from
 effluent

 * Based on rate of 1.4158.02/06/2002.