Page 112 - Modern Control of DC-Based Power Systems
P. 112

76                                  Modern Control of DC-Based Power Systems





















          Figure 2.51 Bode plot of the identified output impedance of the source converter com-
          pared to the analytic transfer function with the Digital Network Analyzer technique.






























          Figure 2.52 Voltage and current measurements at the impedance measurement
          point with the Wideband System Identification technique.


          which is f sw =2 5 10kHz in this example. As a concluding remark, the
          WSI is able to excite many more frequencies in the system than the digital
          network analyzer technique in half of the injection time. This is a practical
          advantage in stability analysis applications due to the strict requirement of
          fast impedance measurements over a wide frequency range.
   107   108   109   110   111   112   113   114   115   116   117