Page 88 - Plant design and economics for chemical engineers
P. 88

29. FICA-l fails  Deadhead pump  Damage to pump None  See Event 26.
                                          closing FV-1
                                       30. V-3 open     Reagent released           FICA-1   Estimate  release
                                                                                              quantity.
                               More    31. FV-1 fails open  Upset in reactor  Reagent released FICA-1  Possible problem
                                                                                              in reactor.
                                       32. FICA-l fails,  Upset in reactor  Reagent released None  See Event 31.
                                          opening FV-1
                               Pressure
                               More    33. V-4 closed   Deadhead pump  Damage to pump PI-l,  See Event 26.
                                                                                    FICA-l
                                       34. FV-1 fails closed  Deadhead pump  Damage to pump PI-l,  See Event 26.
                                                                                    FICA-l
                                       35. FICA-1 fails,  Deadhead pump  Damage to pump PI-1  See Event 26.
                                          closing FV-1
                                       36. V-2 and      Deadhead pump  Overpressure  in  PI-l,  Evaluate need for
                                          V-4 closed                    pump or line  FICA-l  hydraulic  relief.
                               Less    37. V-2 closed   Pump  cavitates  Damage to pump PI-l,  See Event 1.
                                                                                    FICA-1
                                       38. V-3 open     Reagent released            PI-1    See Event 3.
                               Temperature
                               More    39. V-4 closed   Deadhead pump  Damage to pump None  See Event 26.
                                       40. FV-1 fails closed  Deadhead pump  Damage to pump None  See Event 26.
                                       41. FICA-l fails,  Deadhead pump  Damage to pump None  See Event 26.
                                          closing FV-1
   83   84   85   86   87   88   89   90   91   92   93