Page 87 - Plant design and economics for chemical engineers
P. 87

TABLE 4
 HAZOP  study results for process in Fig. 3-1  (Continued)
 Equipment  Deviations  Consequences of
 reference  fmm  What event  this deviation on  Additional
 and operating  operating  could cause  item of equipment  implications  of  Process
 conditions  conditions  this  deviation?  under consideration this consequence  indications Notes and questions
 20. Volatile impurity  Reagent released  Tank rupture if  PICA-1  Consider  independent
 in feed  via RV-1  RV-1 fails  PAH.
                              Consider  sampling
                                before  unloading.
 No  Same as less
 Temperature
 Less  21. Temperature of  Possible vacuum  Thermal  stress  What are temperature
 inlet is colder  (see less pressure)  on tank  limits of tank%
 than normal
 22. Low tank  See Events lo-13  Thermal stress  What are pressure
 pressure  on tank              limits of tank?
 More  23. Temperature of  See Event 18  Thermal  stress  What are temperature
 inlet is hotter  on tank       limits of tank?
 than normal
 24. External fire  Tank fails  Reagent released  What could cause an
                                external  fire?
                              What are fire-protec-
                                tion capabilities?
                              Is fire protec-
                                tion adequate?
 Feed pump  Flow
 P-l  Less  25. V-2 closed  Pump  cavitates  Damage to pump FICA-l  See Event 1.
 26. V-4 closed  Deadhead pump  Damage to pump FICA-l  Any other problem
                                with deadhead?  ’
 27. Line plugs  Pump  cavitates  Damage to pump FICA-l  See Event 1.
 28.  FV-1 fails closed  Deadhead pump  Damage to pump FICA-1  See Event 26.
   82   83   84   85   86   87   88   89   90   91   92