Inverter circuits   297
                    inverter losses, caused  by  the  circulation  of  commutation  current  (for
                    example, via L1-D1-C-THz) make it inefficient at high frequencies. The
                    most usual voltage-control system consists of two parallel inverters, with a
                    common secondary, whose square wave outputs are phase shifted to give a
                    mark-space controlled voltage output.





















                         13.12 Parallel capacitor commutated push-pull  inverter with individual ann control
                      Figure  13.12 shows  a  commutation  system  which  permits individual
                    thyristor turn-off. Whilst TH1 is conducting thyristor 'Il& is fired, which
                    charges C, to 2vB with plate a positive. When   turns on, thyristor THI
                    being previously turned off, capacitor C, discharges through it and b-D4,
                    recharging with plate b positive. To turn THz off thyristor TH, is again
                    fired to connect capacitor C, across it. Thyristor TH1 can be fired later in
                    the cycle as required, the greater the delay between the turning off of one
                    thyristor and  the  firing of  the  next,  the  lower  the  output voltage.  As
                    mentioned above,  it  is  important to bear  in  mind  that  this  is  not  true
                    mark-space control since the inductive load current would normally be
                    decaying through feedback diodes D1 and Dz. Therefore the load voltage
                    at any inverter setting is determined by the magnitude of  the load current
                    and its power factor.
                      Figure  13.13(a)  shows  a  single-phase  bridge  inverter  circuit  using
                    parallel-capacitor commutation. With TH1 and TI& conducting, capacitor
                    C is charged to VB with plate a positive. When THz and TH3 are fired to
                    commence the next step of the output, capacitor C is connected across THI
                    and  TH,  and  turns  them  off.  The  circuit  is  therefore an  example  of
                    parallel-capacitor commutation in which inductors L1 prevent the supply
                    from  being  instantaneously short-circuited  during commutation. Figure
                    13.13(b) shows an extension to a three-phase inverter, where firing any
                    thyristor which has positive anode voltage will commutate all the other
                    conducting thyristors in its row.
                      An alternative parallel capacitor commutated bridge  is  illustrated in
                    Figure  13.14.  An  auxiliary  d.c.  supply  is  shown  connected  to  the
                    commutation circuit to enable the main supply to be varied, for example to
                    control the magnitude of  the output voltage. Where this is not required a
                    separate supply is not essential and can be shorted out. When TH7 is fired
   302   303   304   305   306   307   308   309   310   311   312