Heating and Lighting   409


















































                      1                                          I
                   (b)                              Load
                    Figure 14.59 Simple phase-control circuits for resistive loads: (a) triac arrangement;
                    (b) single-thyristor and diode bridge arrangement

                    sufficiently high value before the trigger diodes break over. Zener diodes can
                    be used in place of the trigger devices but then the magnitude of the trigger
                    pulse is reduced, once the diodes start conducting, and the range of control
                    is also less. Power loss in the controlling potentiometers of both these circuits
                    is  low,  since  once  the  power  device  turns  on  the  voltage  across  the
                    potentiometer falls to a very low value, the loss being minimum at full load,
                    the delay angle being small.